Skip the extra fees and enjoy 10% off when you use code TENOFF at checkout.
image-icon
Still unsure about this products? Chat with us now 24/7 Online
image-icon
Fast
Shipping
image-icon
Online
Support 24/7
image-icon
GST
Included

Ubiquiti UA-G2-SK-PRO G2 Starter Kit Pro

UA-G2-SK-PRO
Ubiquiti
G2 Starter Kit Pro
Out of stock
Only %1 left
SKU
UA-G2-SK-PRO

Have one to sell? Click here

**Product images and accessories are provided by a content provider. The images may vary slightly from the original and are for illustrative purposes. Compatibility guarantee for accessories cannot be guaranteed. The scope of delivery corresponds to the item description (possibly identical item) Please note the product and condition description.

UA-Hub-Door
Mechanical
Dimensions174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3")
Weight363 g (12.8 oz)
Enclosure materialPolycarbonate
Mounting materialPolycarbonate
Hardware
Networking interface(5) 10/100/1000 Base-T
Power methodPoE++
UL 294 Power-limited Class 2 PSU
UL 60950/62368 LPS/PS2 PSU
Max. power consumptionWithout PoE output: 30W
With PoE output: 50W
PoE input50V DC, 1A
PoE outputPoE passthrough, (4) PoE, 50V DC, total 20W
Button(1) Factory-reset
LEDsWhite/blue (Learn more)
Digital inputRequest to exit/request to enter/remote release/door position sensor
Dry output relayLock: 30V DC, 1A
Aux: 30V DC, 1A
Powered output relayLock: 12V DC, 1A
Aux: 12V DC, 0.33A
12V DC, 0.33A
Operating environmentIndoor use only
Ambient operating temperature0 to 40° C (32 to 104° F) 
Ambient operating humidity5 to 95% noncondensing
UL 294 levelDestructive attack: Level I
Line security:  Level I
Endurance: Level I
Standby power: Level I
UL 294 statementCompliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 GradeGrade assignment: 1
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-Hub-Door002, V01
Wiring Information
Wiring gauge requirements (AWG)
Total length to deviceOutput load current at 12V DC
100mA250mA500mA1A       
6.1 m (20 ft)22222218
15.2 m (50 ft)22222218
30.5 m (100 ft)22221818

UACC-Cable-DoorLockRelay (18 AWG) is recommended.
PoE cabling requirementsThe minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 24 AWG (0.21 mm 2 ) for horizontal or riser cable.
UA-G2-Pro
Mechanical
Dimensions160 x 40.4 x 40.55 mm (6.3 x 1.59 x 1.6")
Weight136 g (4.8 oz)
Enclosure materialPolycarbonate, glass
Mount materialAluminum alloy
MountingWall, gang box
WeatherproofingIP55
Hardware
Networking interface(1) GbE RJ45 port
ConnectivityBLE 4.2
NFC
Power methodPoE
UL 294 Power-limited Class 2 PSU
UL 60950-1/62368-1 LPS/PS2 PSU
Supported voltage range48V DC
Max. power consumption6W
ESD/EMP protectionAir: ±15kV, contact: ±8kV
SensorProximity sensor
Camera view angleH: 96.67°, V: 123.15°, D: 153.11°
MicrophoneYes
Speaker(1) 4 ohm, 1.5W
LEDsR/G/B/W/Amber (Learn more)
Button(1) Factory-reset
NFC frequency13.56 MHz
NFC read range< 30 mm
NFC standardsISO 14443A, 14443B, 15693
NFC technologyNFC Tag 1,2,3,4,5
MIFARE Classic
MIFAREPlus
MIFARE Ultralight
MIFARE DESFire
Operating environmentOutdoor use
Ambient operating temperatureDevice: -30 to 45° C (-22 to 113° F)
Display:* -10 to 45° C (14 to 113° F)
*The display will turn off when the ambient temperature is above/below the display operation temperature, but other functions will remain functional. (Effective after firmware v1.3.28)
Ambient operating humidity5 to 90% noncondensing
Software informationThe software version of a product can be checked at https://unifi.ui.com
UL 294 levelDestructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level I
UL 294 statementCompliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
PoE cabling requirementsCable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords; 24 AWG (0.21 mm 2 ) for horizontal or riser cable.
CAN/ULC-60839-11-1 GradeGrade assignment: I
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-G2-Pro/UA-G2-Pro-Black, V02
UA-G2
Mechanical
Dimensions93 x 40 x 36.5 mm (3.7 x 1.6 x 1.4")
Weight82 g (2.9 oz)
Enclosure materialPolycarbonate, glass
MountingIn wall, gang box
WeatherproofingIP55
Hardware
Networking interface(1) 10/100 MbE RJ45 port
ConnectivityBLE 4.1
Power methodPoE
UL 294 Power-limited Class 2 PSU
UL 60950-1/62368-1 LPS/PS2 PSU
Supported voltage range48V DC
Max. power consumption5W
ESD/EMP protectionAir: ±15kV, contact: ±8kV
SensorsProximity sensor
Speaker(1) 8 ohm, 0.7W
LEDsR/G/B/W (Learn more)
Button(1) Factory-reset
NFC frequency13.56 MHz
NFC read range< 30 mm
NFC standardsISO 14443A, 14443B, 15693
NFC technologyNFC Tag 1,2,3,4,5
MIFARE Classic
MIFAREPlus
MIFARE Ultralight
MIFARE DESFire
Operating environmentOutdoor use
Ambient operating temperature-30 to 45° C (-22 to 113° F)
Ambient operating humidity5 to 90% noncondensing
Software informationThe software version of a product can be checked at https://unifi.ui.com
UL 294 levelDestructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level I
UL 294 statementCompliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
PoE cabling requirementsCable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords; 24 AWG (0.21 mm 2 ) for horizontal or riser cable.
CAN/ULC-60839-11-1 GradeGrade assignment: I
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-G2/UA-G2-Black, V02
UA-Pocket
Mechanical
Dimensions84 x 39 x 7.4 mm (3.3 x 1.5 x 0.29")
Weight16 g (0.56 oz)
Enclosure materialPolycarbonate, stainless steel
WeatherproofingIP54
Hardware
NFC frequency13.56 MHz
NFC technologyISO/IEC 14443 Type A
MIFARE DESFire EV3 4K
UniFi Access Proprietary Security Protocol
Ambient operating temperature-10 to 45° C (14 to 113° F)
Ambient operating humidity10 to 90% noncondensing
CertificationCE
The lowest prices guaranteed
Prology provides the highest quality products at the lowest possible prices for our clients. Please contact us if you see a lower price and we guarantee to beat any genuine offer from a competitor.
Quality Guaranteed
Every second-user Cisco Systems device from Prology is fully refurbished. Accessories are then added as appropriate, and the unit is professionally re-packaged ready for despatch. The entire process takes under 24 hours. Nearly all of our pre-owned and refurbished network equipment is sold in a new or ‘as new’ condition. We can provide detailed reports on the condition of any item. See Our Testing procedures: 24-point Quality Control Program
Money-Back Guarantee
As long as your equipment is still covered by warranty, you can contact our customer service team to exchange or return any faulty product that you have purchased from us.
Flexible Secure Payment & Shipment
Depending on the size of your order, shipping will be done via Australia Post|FedEx | DHL | UPS | TNT | CourierPlease.
Major Payment Method Accepted: Visa/ MasterCard/ American Express/ PayPal.
365-day repair or replace warranty
  • Every piece of refurbished networking equipment sold by Prology is fully-guaranteed and comes with a 6-month warranty.
  • Prology warranties and returns are subject to acceptance of, and compliance with, Prology policies and procedures as described above and on Prology Online RMA form.
  • We offer an industry-leading 365-day warranty* on all of our refurbished products.
* Retail, end-user clients only. Wholesale clients are subject to a 30-day repair or replace warranty.
The Support Contacts
If your Cisco products experience a failure, you must contact your sales representative to verify the product issue. If the problem cannot be corrected by remote support methods i.e. email or phone support, the RMA process will commence immediately.
DELIVERY INFOMATION
Our Logistic Partners
Useful Information about our shipping:
  • Item allocation for your order will usually take 1-3 business days depending on stock availability after your payment has been received
  • Shipping time will apply after the above mentioned period
  • Low cost – all items from your order are usually packed together for a convenient single delivery so that you can save on shipping
  • Shipping calculator with various delivery options for entire order is located on the shopping cart page
Payment Information
Major Payment Method Accepted:
  • BPAY – No Fees
  • Bank Transfer – No Fees
  • Credit Cards – 1% transaction fee for VISA, MasterCard, 2% transaction fee for AMEX
  • PayPal – 1% transaction Fee
© Prology Inc. All copyrights, trademarks and tradenames are acknowledged. Prology Inc hold no affiliation to any of the Trademark owners. Powered by APACTech.io